Which distance relay is least affected by arc resistance and is preferred for short transmission lines?

AReactance relay
BImpedance relay
CMho relay
DThermal relay
Submitted by: mcqstutor Team 0 comments

Buchholz relay is a gas-actuated protective relay used exclusively for:

ASynchronous motors
BHigh-voltage alternators
CAir-cooled transformers
DOil-immersed transformers
Submitted by: mcqstutor Team 0 comments

The Merz-Price circulating current scheme for transformer protection operates on the principle of:

AOvercurrent protection
BNegative sequence detection
CDifferential protection
DDistance relaying
Submitted by: mcqstutor Team 0 comments

Which power system fault is classified as a symmetrical fault?

ASingle line-to-ground fault
BDouble line-to-ground fault
CThree-phase fault (L-L-L or L-L-L-G)
DLine-to-line fault
Submitted by: mcqstutor Team 0 comments

Bundled conductors are widely used in High Voltage (HV) and Extra High Voltage (EHV) transmission lines to:

AIncrease mechanical tension
BEliminate skin effect entirely
CReduce conductor weight
DReduce corona loss and line reactance
Submitted by: mcqstutor Team 0 comments

Proximity effect in a transmission line conductor results in:

ADecrease in effective line resistance
BComplete cancellation of line inductance
CNon-uniform current distribution due to magnetic flux from neighboring conductors
DUniform current distribution across cross-section
Submitted by: mcqstutor Team 0 comments

Which type of fault in a 3-phase power transmission line is the most frequent?

ADouble Line-to-Ground (L-L-G) fault
BSingle Line-to-Ground (L-G) fault
CLine-to-Line (L-L) fault
DSymmetrical Three-Phase fault (L-L-L)
Submitted by: mcqstutor Team 0 comments

The surge impedance of an underground cable is significantly lower than overhead lines, usually around:

A40 to 50 ohms
B5 to 10 ohms
C1000 ohms
D400 to 500 ohms
Submitted by: mcqstutor Team 0 comments

An over-excited synchronous motor operating on no-load acts as a:

ASynchronous condenser
BInductive load
CResistive heater
DStep-down transformer
Submitted by: mcqstutor Team 0 comments

The surge impedance of a typical overhead transmission line is approximately in the range of:

A400 to 500 ohms
B10 to 20 ohms
C1000 to 2000 ohms
D40 to 50 ohms
Submitted by: mcqstutor Team 0 comments