The Thermal Runaway phenomenon in a BJT amplifier is primarily caused by:

ABreakdown of emitter insulation
BBase width modulation
CExcessive gate voltage applied to collector
DUncontrolled cumulative increase in collector current due to temperature rise
Submitted by: mcqstutor Team 0 comments

An ideal operational amplifier has input impedance R_in and output impedance R_out equal to:

AR_in = infinity, R_out = 0
BR_in = infinity, R_out = infinity
CR_in = 0, R_out = infinity
DR_in = 100 kOhm, R_out = 50 Ohm
Submitted by: mcqstutor Team 0 comments

Which semiconductor device exhibits negative differential resistance region in its I-V characteristics?

AVaractor Diode
BTunnel Diode
CZener Diode
DSchottky Diode
Submitted by: mcqstutor Team 0 comments

The surge impedance of an underground power cable is approximately:

A400 Ohms to 500 Ohms
B4000 Ohms
C5 Ohms
D40 Ohms to 50 Ohms
Submitted by: mcqstutor Team 0 comments

A p-n junction diode under reverse bias condition has a depletion region width that:

ABecomes zero
BDecreases
CRemains constant
DIncreases
Submitted by: mcqstutor Team 0 comments

Arc extinction in a High Voltage AC Circuit Breaker is achieved by:

AApplying DC reverse voltage
BIncreasing arc resistance to infinity instantly
CIncreasing dielectric strength of the medium between contacts
DShorting the contacts permanently
Submitted by: mcqstutor Team 0 comments

A symmetrical 3-phase fault on a power transmission system is characterized by:

AEqual fault currents in all three phases spaced 120 degrees apart
BUnbalanced phase voltages
CHigh zero-sequence current flow
DDominant negative-sequence components
Submitted by: mcqstutor Team 0 comments

The standard per-unit impedance Z_pu of a system component on new base quantities is calculated using:

AZ_pu(new) = Z_pu(old) * (MVA_old / MVA_new)^2
BZ_pu(new) = Z_pu(old) * (kV_old / kV_new)^2 * (MVA_new / MVA_old)
CZ_pu(new) = Z_pu(old) * (kV_new / kV_old)^2 * (MVA_new / MVA_old)
DZ_pu(new) = Z_pu(old) * (kV_new / kV_old) * (MVA_old / MVA_new)
Submitted by: mcqstutor Team 0 comments

Corona loss in an overhead transmission line increases significantly during:

ALow voltage operation
BHot dry summer days
CStormy and humid weather
DSmooth conductor surface conditions
Submitted by: mcqstutor Team 0 comments