Euler’s critical buckling load for a column hinged at both ends is given by:

A(pi^2 * E * I) / (4 * L^2)
B(pi^2 * E * I) / L^2
C(2 * pi^2 * E * I) / L^2
D(4 * pi^2 * E * I) / L^2

Explanation

Euler’s buckling load formula is P_cr = (pi^2 * E * I) / (Le)^2. For both ends hinged/pinned, effective length Le = L, so P_cr = (pi^2 * E * I) / L^2.