Dummy coils are used in DC armatures with wave winding to:
AEliminate commutation spark
BIncrease generated emf
CMaintain mechanical balance of the armature rotor
DReduce armature reaction
Explanation
Dummy coils are inactive coils added to wave-wound armature windings of DC machines solely to ensure complete mechanical symmetry and balance of the rotating armature. They are insulated and not connected into the electrical circuit.