Kelvin’s Double Bridge is designed to eliminate lead and contact resistances when measuring:

AMedium resistances
BVery low resistances (< 1 ohm)
CInductive reactances
DHigh insulation resistances

Explanation

Kelvin’s double bridge utilizes two sets of ratio arms to cancel lead wire resistance, rendering accurate low resistance measurements.